ALARMS

Forensic Detectors FD-D001 Memory Function & User Manual

The Forensic Detectors FD-D001 is a Low Level & Fast CO (Carbon Monoxide) Detector that triggers an audible alarm when CO detected > 25ppm. View for memory function, manual and troubleshooting steps.

FD-D001 Low Level & Fast Carbon Monoxide Alarm User Manual

FD-D001 Peak Memory Function

After an alarm event, the CO alarm stores in memory the alarm event – CO concentration level. The detector has memory slots CO, C1…C9. By pressing the MENU Button, the memory location will be shown and then press TEST button to see the numerical ppm value that was recorded.

Press MENU again to go to the next memory slot. Keep pressing MENU and eventually you will reach to “dEL”, which means delete the memory if you wish. Please note the most recent memory slot is CO. As alarm events occur they will be pushed up the array, so the memory slot C0 will always store the most recent alarm value. This is a useful function. For example, after leaving the home, one can check the memory to see if a alarm was triggered when absent from the home.

Forensic Detectors FD-D001 Low Battery Signal

At the battery lowest point, you will hear a single “beep” every 45 seconds and the POWER LED will blink. This is the low battery alarm and indicates to immediately change the batteries. Always replace with 3 x AA Alkaline batteries.

Fault Signal:

The unit may experience failure. If it does, it will indicate this by blinking the FAULT LED, twice with simultaneous “beeps” which repeat every 22 seconds – in addition “Err” will be displayed. Please replace the unit.

End of Alarm Life Warning

When product is at the end of life, the LCD screen displays “EnD”. Immediately replace the detector. Also, if the PRODUCTION DATE plus 10 years has been exceeded, please also replace the detector even if the END OF ALARM LIFE has not been triggered. As the detector ages, it reduces in sensitivity.

Usage Warning:

  • UNIT DESIGNED ONLY FOR INDOOR USE
  • DO NOT TAMPER and DO NOT OPEN THE UNIT
  • NOT TO BE USED IN CORROSIVE GAS
  • DO NOT BLOCK THE GRILLED VENTS /
  • THE UNIT CANNOT sustain EXCESSIVE
  • THIS IS NOT A SMOKE OR FIRE
  • DO NOT PAINT ON OR NEAR THE MONITOR
  • DO NOT SPRAY AIR REFRESHENER, CLEANING SUPPLIES, OR INSECT KILLER NEAR THE UNIT.
  • UNIT DESIGNED ONLY FOR INDOOR USE,
  • DO NOT TEST THE UNIT WITH EXHAUST GAS
  •  DISPOSE UNIT 5 YEARS after Production Date.
  • DEPRESS THE TEST BUTTON WEEKLY

Recommended Locations For FD-D001 CO Detector Installation

Like all CO alarms, the Forensic Detectors FD-D001 Low Level & Fast CO Detector should be mounted in or near bedrooms and living areas. It is recommended that you install the CO alarm (at minimum) on each level of your home. When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install only one CO alarm in your home, install it near bedrooms, not in the basement or furnace room. When wall mounting, keep it out of the reach of children, pets or accidental bumps. Under no circumstances should children be allowed to handle the CO alarm. Placing the alarm at eye level is recommended as it allows for optimum daily monitoring of the digital display.

Installation Guide

The detector comes with batteries included in the battery compartment. Open the compartment by sliding the battery cover. Remove the plastic covering the batteries. The Detector then turns ON. Establish a mount location considering the prior locations to avoid. Having established the mounting location, ensure that there is no electrical wiring or pipe work in the area adjacent to the mounting surface. The detector comes with (a) mount plate (b) 2 x screw

  • (c) 2 x plastic drywall expansion anchors.
  • Remove the mount plate from the detector by sliding it off. Mark the two mount hole locations on a wall using the backplate holes as a guide.
  • Drill holes in the positions marked using a 5mm drill bit.
  • Insert the plastic drywall expansion anchors.
  • Install the mount plate, align the holes and screw the screws into the anchors.
  • Slide the detector onto the mount plate.
  • The detector is ready for continuous operation.
  • For tabletop placement, simply place the CO alarm on the table, so that the users can see the alarm clearly